Part Number Hot Search : 
ZTX555 A1150 C1024 BCX5210 LC721 HT162009 160BC C0603A
Product Description
Full Text Search
 

To Download HAT200-S Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Current Transducer HAT 200..1500-S
For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN = 200..1500 A VOUT = 4 V
Electrical data
Primary nominal r.m.s. current IPN (A) 200 400 500 600 750 800 1000 1200 1500 Primary current measuring range 4) IP (A) 600 1200 1500 1800 2250 2400 3000 3000 3000 Type
HAT HAT HAT HAT HAT HAT HAT HAT HAT
200-S 400-S 500-S 600-S 750-S 800-S 1000-S 1200-S 1500-S
Features
* Hall effect measuring principle * Galvanic isolation between primary * * * *
and secondary circuit Isolation voltage 3000 V Low power consumption Extended measuring range( 3 x IPN) Insulated plastic case recognized according to UL 94-V0
VC IC R IS VOUT ROUT RL
Supply voltage ( 5 %) 4) Current consumption Isolation resistance @ 500 VDC Output voltage @ IPN, RL = 10 k, TA = 25C Output internal resistance Load resistance
15 15 > 1000 4 100 > 10
V mA M V k
Advantages
* Easy mounting * Small size and space saving * Only one design for wide current
ratings range
Accuracy-Dynamic performance data
X
L
VOE VOH VOT TC G tr f
Accuracy @ IPN, TA = 25C (without offset) Linearity error 1) (0 .. IPN) Electrical offset voltage, TA = 25C Hysteresis offset voltage @ IP = 0; after an excursion of 1 x IPN Thermal drift of VOE Thermal drift of the gain (% of reading) Response time @ 90% of IP Frequency bandwidth 2) (- 3 dB)
< 1 % of IPN < 1 % of IPN < 20 mV < 10 mV <1 mV/K < 0.1 %/K <5 s DC .. 25 kHz
* High immunity to external
interference.
Applications
* DC motor drives * Switched Mode Power Supplies
(SMPS)
General data
TA TS m Ambient operating temperature - 10 .. + 80 Ambient storage temperature HAT 200-S, HAT 500..1500-S - 15 .. + 85 HAT 400-S - 25 .. + 85 Mass 300 UL94 classification V0 C C C g
* AC variable speed drives * Uninterruptible Power Supplies
(UPS)
* Battery supplied applications * Power supplies for welding
applications
Notes :
1) 2)
Linearity data exclude the electrical offset. Please refer to derating curves in the technical file to avoid excessive core heating at high frequency. 3) Please consult characterisation report for more technical details and application advice. 4) Operating at 12V Vc < 15V will reduce the measuring range.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
051011/9
Page 1/3
LEM Industrial
www.lem.com
Current Transducer HAT 200..1500-S
Isolation characteristics
Rated Voltage with IEC 61010-1 standards and following conditions - Reinforced insulation - Over voltage category III - Pollution degree 2 - Heterogeneous field R.m.s. voltage for AC isolation test, 50 Hz, 1 mn Creepage distance Clearance distance Comparative Tracking Index (Group IIIa) 1000 V
Vd dCp dCl CTI Notes :
3 > 11 > 11 275
kV mm mm
051011/9
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. Page 2/3
LEM Industrial
www.lem.com
Dimensions HAT 200..1500-S (in mm. 1 mm = 0.0394 inch) Top view
H AT-S SERIES
12 = = 12 = =
(unit = mm)
H AT 500-S to 1 500-S
Positive curren flow current t
70
10
12
5
30.5 x 40.5
1
15.5
4
Molex 5045-04A 6
78
4
10
30
65
46 Max.
24
29
38
1
Front view
H AT 200-S
4
90
1 (+)
All holes O 4.5mm
Pins arrangement 2 3 (-) Output
4 0V
Fixation by base-plate or on bus bar
Mechanical characteristics
* General tolerance * Transducer fastening
30.5 x 40.5
Safety
with M screws 4
* Connection of secondary
1 mm By base-plate 1or on 432 bus bar Molex 5045-04A with M4 screws. All slots 4.5 mm Molex 5045-04A
Pins arrangement: 1 (+) 2 (-) 3 Output 4 0V
This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements 99/05 in accordance with the following manufacturer's operating instructions.
Caution, risk of electrical shock
Remarks
* IS is positive when IP flows in the direction of the arrow. * Temperature of the primary conductor should not exceed
100C.
When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a built-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. 051011/9
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
Page 3/3
LEM Industrial
www.lem.com


▲Up To Search▲   

 
Price & Availability of HAT200-S

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X